[Mono-list] PROGRESS!! Re: Invalid data from CP2102 USB device

Steve Ricketts velocedge at hotmail.com
Tue Apr 13 10:39:14 EDT 2010


I now know the problem, but not the solution.  I've been fighting this almost
non-stop for days and overlooked a key piece of information.  On Windows,
I'm using a baud rate of 128000.  Very early on, I had to change the rate to
115200 in Linux because the 128000 is non-standard.  I just changed the baud
rate in Windows to 115200 and got the same input as I'm getting in Linux!

It works in Windows with baud rates of 125000, 128000, 127117 but not 115200
Linux will only allow 115200 (CP210x docs say 127117 should be allowed)

So, the baud rate is the problem.  Now... what's the solution??  How can I
set a non-standard baud rate for the CP2102?

So close... so close...
-- 